multimon.conf (2344B)
1 # Sample multimon configuration file 2 # 3 # This file is not required. Without it, multimon will use the default 4 # field layout. 5 # 6 # Temperature selection 7 # 8 # Pick "TEMPC" for Celsius or "TEMPF" for Fahrenheit. This will override 9 # the --enable-celsius setting from the compile. UPSTEMP (below) will 10 # use this setting by default. 11 12 TEMPC 13 14 # Format: 15 # FIELD <variable> "<field name>" "<field suffix>" 16 # 17 # <variable> is either a word from the UPS protocol like battchg (see the 18 # table in src/cgi/upsfetch.c) or a special word in uppercase. 19 # 20 # Special words are: 21 # MODEL - Show the model name for this system in cyan 22 # 23 # STATUS - Parse the status for this system using the appropriate color 24 # 25 # UPSTEMP and AMBTEMP use the default scale. This is set to C if you use 26 # --enable-celsius at compile time *or* if you use "TEMPC" above. 27 # 28 # UPSTEMP - Show the UPS temperature in the default scale (suffix ignored) 29 # AMBTEMP - Show the ambient temperature in the default scale (suffix ignored) 30 # 31 # UPSTEMPC - Show the UPS temperature in degrees C (suffix ignored) 32 # UPSTEMPF - Show the UPS temperature in degrees F (suffix ignored) 33 # AMBTEMPC - Show the ambient temperature in degrees C (suffix ignored) 34 # AMBTEMPF - Show the ambient temperature in degrees F (suffix ignored) 35 # 36 # They're called "special" since they actually understand the content 37 # being printed and do other things based on what's in there. 38 # 39 # <field name> is what you'd like this column to be called on the page. 40 # Remember that this is HTML, so you can actually embed markup in here. 41 # This means you can even include images here. You can include quotes 42 # (and backslashes!) in the string by escaping them with a backslash (\). 43 # 44 # <field suffix> is typically something like % or VAC. It's useful if 45 # you want to convey the units that apply to a value. 46 # 47 # Example config 48 49 FIELD SYSTEM "System" "" 50 FIELD MODEL "Model" "" 51 FIELD STATUS "Status" "" 52 FIELD battpct "Battery Chg" "%" 53 FIELD utility "Utility" "VAC" 54 FIELD loadpct "UPS Load" "%" 55 FIELD UPSTEMP "UPS Temp" "" 56 FIELD runtime "Batt. Run Time" "min." 57 FIELD DATA "Data" "All data" 58 59 # These are only useful if you have a Smart-UPS model with the Measure-UPS II 60 # measurement card. No other models presently support these features. 61 # 62 # FIELD AMBTEMP "Ambient Temp" "" 63 # FIELD HUMIDITY "Ambient Humidity" "%"