nut-monitor.init (5088B)
1 #!/bin/sh /etc/rc.common 2 3 START=60 4 USE_PROCD=1 5 UPSMON_C=/var/etc/nut/upsmon.conf 6 7 nut_upsmon_conf() { 8 local cfg="$1" 9 10 echo "# Config file automatically generated from UCI config" > $UPSMON_C 11 12 config_get runas "$cfg" runas "nut" 13 [ -n "$runas" ] && echo "RUN_AS_USER $runas" >> $UPSMON_C 14 15 config_get val "$cfg" minsupplies 1 16 echo "MINSUPPLIES $val" >> $UPSMON_C 17 18 config_get val "$cfg" shutdowncmd "/sbin/halt" 19 echo "SHUTDOWNCMD \"$val\"" >> $UPSMON_C 20 21 config_get val "$cfg" notifycmd 22 [ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> $UPSMON_C 23 24 config_get val "$cfg" pollfreq 5 25 echo "POLLFREQ $val" >> $UPSMON_C 26 27 config_get val "$cfg" pollfreqalert 5 28 echo "POLLFREQALERT $val" >> $UPSMON_C 29 30 config_get val "$cfg" hostsync 15 31 echo "HOSTSYNC $val" >> $UPSMON_C 32 33 config_get val "$cfg" deadtime 15 34 echo "DEADTIME $val" >> $UPSMON_C 35 36 config_get val "$cfg" powerdownflag /var/run/killpower 37 echo "POWERDOWNFLAG $val" >> $UPSMON_C 38 39 config_get val "$cfg" onlinemsg 40 [ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> $UPSMON_C 41 config_get val "$cfg" onbattmsg 42 [ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> $UPSMON_C 43 config_get val "$cfg" lowbattmsg 44 [ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> $UPSMON_C 45 config_get val "$cfg" fsdmsg 46 [ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> $UPSMON_C 47 config_get val "$cfg" commokmsg 48 [ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> $UPSMON_C 49 config_get val "$cfg" commbadmsg 50 [ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> $UPSMON_C 51 config_get val "$cfg" shutdownmsg 52 [ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> $UPSMON_C 53 config_get val "$cfg" replbattmsg 54 [ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> $UPSMON_C 55 config_get val "$cfg" nocommmsg 56 [ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> $UPSMON_C 57 config_get val "$cfg" noparentmsg 58 [ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> $UPSMON_C 59 60 notifylist() { 61 local value="$1" 62 append optval "$value" "+" 63 } 64 65 setnotify() { 66 local cfg="$1" 67 local optname="$2" 68 local optval 69 config_list_foreach "$cfg" "$optname" notifylist 70 if [ -z "$optval" ]; then 71 # If no list fallback to trying option, fallback to default 72 config_get optval "$cfg" "$optname" "$default" 73 if [ -n "$optval" ]; then 74 echo "$optval" 75 else 76 # No default, so do the NUT default 77 echo "SYSLOG" 78 fi 79 else 80 echo "$optval" 81 fi 82 } 83 84 local default optval 85 val="" 86 config_list_foreach "$cfg" defaultnotify notifylist 87 default="$optval" 88 echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" >> $UPSMON_C 89 echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" >> $UPSMON_C 90 echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" >> $UPSMON_C 91 echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" >> $UPSMON_C 92 echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" >> $UPSMON_C 93 echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" >> $UPSMON_C 94 echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" >> $UPSMON_C 95 echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" >> $UPSMON_C 96 echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" >> $UPSMON_C 97 echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" >> $UPSMON_C 98 99 config_get val "$cfg" rbwarntime 43200 100 echo "RBWARNTIME $val" >> $UPSMON_C 101 102 config_get val "$cfg" nocommwarntime 300 103 echo "NOCOMMWARNTIME $val" >> $UPSMON_C 104 105 config_get val "$cfg" finaldelay 5 106 echo "FINALDELAY $val" >> $UPSMON_C 107 108 config_get val "$cfg" certpath 109 if [ -n "$val" ]; then echo "CERTPATH $val" >> $UPSMON_C; fi 110 111 config_get_bool val "$cfg" certverify 0 112 if [ -n "$val" ]; then echo "CERTVERIFY $val" >> $UPSMON_C; fi 113 114 config_get_bool val "$cfg" forcessl 0 115 if [ -n "$val" ]; then echo "FORCESSL $val" >> $UPSMON_C; fi 116 } 117 118 nut_upsmon_add() { 119 local cfg="$1" 120 local type="$2" 121 local upsname 122 local hostname 123 local port 124 local powervalue 125 local username 126 local password 127 local system 128 129 # If no core config, use defaults 130 [ -r $UPSMON_C ] || nut_upsmon_conf "" 131 132 config_get upsname "$cfg" upsname 133 config_get hostname "$cfg" hostname localhost 134 config_get port "$cfg" port 135 config_get powervalue "$cfg" powervalue 1 136 config_get username "$cfg" username 137 config_get password "$cfg" password 138 system="$upsname@$hostname" 139 if [ -n "$port" ]; then 140 system="$system:$port"; 141 fi 142 echo "MONITOR $system $powervalue $username $password $type" >> $UPSMON_C 143 } 144 145 start_service() { 146 rm -f $UPSMON_C 147 148 config_load nut_monitor 149 150 config_foreach nut_upsmon_conf upsmon 151 config_foreach nut_upsmon_add master master 152 config_foreach nut_upsmon_add slave slave 153 154 [ -z "$(cat /var/etc/nut/nut.conf)" ] && echo "MODE=netclient" >>/var/etc/nut/nut.conf 155 156 chmod 640 $UPSMON_C 157 chmod 640 /var/etc/nut/nut.conf 158 159 [ -d /var/run/nut ] || { 160 mkdir -m 0750 -p /var/run/nut 161 chown ${runas:-root}:$(id -gn ${runas:-root}) /var/run/nut 162 } 163 164 chown ${runas:-root}:$(id -gn ${runas:-root}) $UPSMON_C 165 $DEBUG /usr/sbin/upsmon $UPSMON_OPTIONS 166 } 167 168 stop_service() { 169 [ -r $PID_F ] && /usr/sbin/upsmon -c stop 170 rm -f $UPSMON_C 171 } 172 173 reload_service() { 174 upsmon -c reload 175 }